Tuesday, July 16, 2013

CLASS NOT REGISTERED ERROR

Meghdoot Millennium Software error in windows 7 



While opening Meghdoot Module it shows an warning message as "Class not Registered"

Method 1: 

Download tool for register Point of sale, Speednet, Treasury dlls
Install MDAC from Meghdoot 7.0 Support folder.
If Problem Not Fixed Try Method 2.

Method 2:
Run SFC scan. System File Checker (sfc) scan will make Windows replace corrupt or missing system files on your computer.

Steps to perform sfc scan:
  • Click Start, click All Programs, click Accessories, right-click Command Prompt, and select Run as Administrator.
  • Click Continue or supply Administrator credentials if prompted.
  • In the Command Prompt window type the following, and press Enter:
  • sfc /scannow


DESPATCH MODULE ERROR : INVALID PROPERTY VALUE :
Error:
          while updating office master updation in despatch module it shows error "Invalid property value". 

                         


Solution:
           
  • Take backup RNet Communication folder and uninstall.
  • Install RNet Communication in some other drive. 
  • Request for office master data through RNet communication.
  • Once it is received, please update the using Despatch module.
POSTMAN DATABASE NOT AVAILABLE

n treasury module while entry in postman returns error shown 'POSTMAN DATA BASE IS NOT AVAILBLE QUITTING'

Solution:


Run the following query using query analyzer
Note:replace ‘myserver’ with your server name

exec sp_serveroption @server='myserver', @optname='rpc', @optvalue='true'
go
exec sp_serveroption @server='myserver', @optname='rpc out', @optvalue='true'
go





DB analyzer Consolidated report ERROR

Problem:
             Most of the Post office while running DB analyzer Consolidated report adp13m6.exe not open/ closed immediately after open cmd window from the DB Analyzer version 02/07/2013 itself. 


Solution:
  • To execute Consolidated report in Db Analyzer minimum requirement is .Net frame work 3.5.
  • Download .Net Framework 3.5 SP1 download from Microsoft website.
  • Install Into your windows operating system i.e Windows 2003 server, Windows XP.



Note: To run DB Analyzer Consolidated Report .Net Framework 3.5 Should be installed in the same Machine

Note: No Need to install .net framework 3.5 SP1 for Windows vista and windows 7 or higher version.

With out .Net framework 3.5 DB analyzer Consoldated Report not possible.

THANKS TO : POTOOLS.BLOGSPOT.COM